The IP Code, International Protection Marking, which consist of two digits.

The first digit indicates the level of protection that the enclosure provides against access to hazardous parts.

The second digit indicates the level of protection that the enclosure provides against harmful ingress of water.

First digit: Solid particle protection

Level sizedEffective againstDescription
0No protection against contact and ingress of objects
1>50 mmAny large surface of the body, such as the back of a hand, but no protection against deliberate contact with a body part
2>12.5 mmFingers or similar objects
3>2.5 mmTools, thick wires, etc.
4>1 mmMost wires, slender screws, large ants etc.
5Dust protectedIngress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment.
6Dust tightNo ingress of dust; complete protection against contact (dust tight). A vacuum must be applied. Test duration of up to 8 hours based on air flow.

Second digit: Liquid ingress protection

LevelProtection againstEffective against
0None
1Dripping waterDripping water (vertically falling drops) shall have no harmful effect on the specimen when mounted in an upright position onto a turntable and rotated at 1 RPM.
2Dripping water when tilted at 15°Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle of 15° from its normal position. A total of four positions are tested within two axes.
3Spraying waterWater falling as a spray at any angle up to 60° from the vertical shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with a counterbalanced shield.Test a) is conducted for 5 minutes, then repeated with the specimen rotated horizontally by 90° for the second 5-minute test. Test b) is conducted (with shield in place) for 5 minutes minimum.
4Splashing of waterWater splashing against the enclosure from any direction shall have no harmful effect, utilizing either: a) an oscillating fixture, or b) A spray nozzle with no shield.Test a) is conducted for 10 minutes. Test b) is conducted (without shield) for 5 minutes minimum.
5Water jetsWater projected by a nozzle (6.3 mm) against enclosure from any direction shall have no harmful effects.
6Powerful water jetsWater projected in powerful jets (12.5 mm nozzle) against the enclosure from any direction shall have no harmful effects.
7Immersion, up to 1 m depthIngress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time (up to 1 m of submersion).
8Immersion, 1 m or more depthThe equipment is suitable for continuous immersion in water under conditions which shall be specified by the manufacturer. However, with certain types of equipment, it can mean that water can enter but only in such a manner that it produces no harmful effects. The test depth and duration is expected to be greater than the requirements for IPx7, and other environmental effects may be added, such as temperature cycling before immersion.

Explore FENIX